vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

ATWS, Terminal Assignments - 16-pin Diagnostic Plug XD > < Function Test for Ultrasonic Sensors

ATWS, Trouble-shooting for Ultrasonic Sensors

 

 

 

 

 

 

 

 

Test

Test

Check

Notes

Nominal

Possible Cause of Fault,

Step

Equipment

 

 

Value

Trouble-shooting

 

Multimeter

of

between

 

 

 

 

 

MKM-587-A

 

 

 

 

 

 

 

1

Voltmeter, range

20 V, DC

Voltage supply, ultrasonic sensor P53

 

 

·   Disconnect wiring harness plugs from ultrasonic sensors P53 and P54

 

·   Wiring harness, interruption/short circuit

     from:    P53/Ter. 2

     to:         K94/Ter. 5

 

 

 

 

 

 

P53/ Ter. 2

P53/ Ter. 3

·   Measure at wiring harness plug P53 (left)

5 to

8 V

 

·   Wiring harness, interruption/short circuit

     from:    P53/Ter. 3

     to:         K94/Ter. 7

 

 

·   Control unit K94 defective

 

 

 

2

Voltmeter, range

20 V, DC

Voltage supply, ultrasonic sensor P54

 

 

·   Disconnect wiring harness plugs from ultrasonic sensors P53 and P54

 

·   Wiring harness, interruption/short circuit

     from:    P54/Ter. 2

     to:         K94/Ter. 5

 

 

 

 

 

 

P54/ Ter. 2

P54/ Ter. 3

·   Measure at wiring harness plug P54 (left)

5 to

8 V

 

·   Wiring harness, interruption/short circuit

     from:    P54/Ter. 3

     to:         K94/Ter. 7

 

 

·   Control unit K94 defective

 

 

 

3

Ohmmeter, range

200 W

Signal lead, ultrasonic sensor P53

P53/ Ter. 1

K94/ Ter. 8

·   Disconnect wiring harness plug from ultrasonic sensor P53

approx.

0 W

·   Wiring harness, interruption

     from:    P53/Ter. 1

     to:         K94/Ter. 8

 

 

 

 

 

 

P53/ Ter. 4

 

K94/ Ter. 10

 

·   Disconnect wiring harness plug from control unit K94

 

 

·   Measure at wiring harness plugs P53 (left) and K94

 

 

approx.

0 W

 

·   Wiring harness, interruption

     from:    P53/Ter. 4

     to:         K94/Ter. 10

 

 

4

Ohmmeter, range

200 W

Signal lead, ultrasonic sensor P54

P54/ Ter. 1

K94/ Ter. 9

·   Disconnect wiring harness plug from ultrasonic sensor P54

approx.

0 W

 

·   Wiring harness, interruption

     from:    P54/Ter. 1

     to:         K94/Ter. 9

 

 

 

 

 

 

P54/

Ter. 4

 

K94/ Ter. 11

 

·   Disconnect wiring harness plug from control unit K94

 

 

·   Measure at wiring harness plugs P54 (right) and K94

 

approx.

0 W

 

·   Wiring harness, interruption

     from:    P54/Ter. 4

     to:         K94/Ter. 11

 

 

 

 

 

ATWS, Terminal Assignments - 16-pin Diagnostic Plug XD > < Function Test for Ultrasonic Sensors