Anti - theft Warning System ATWS Quick Check F5: ACTUATOR TEST
FUEL / CRANK SW.
Conditions for Checking
Nominal Value
Affected Terminals: -
Possible Trouble Codes: 21
Ignition ON
Press F5 in the system main menu. Follow the instructions in the TECH 1 display.
Start Actuator Test
TECH 1 display:
alternating
CLOSED
OPEN
The relay switches
Note:
This is the immobilizer relay used internally in the control unit.
The relay is actuated at a frequency of 0.5 Hz (switch - on time 1 s each).
The test is completed after a maximum of 30 s.