ATWS, Checking the Ultrasonic Sensors

 

Function Test for Ultrasonic Sensors

 

 

For the function test of the four ultrasonic sensors, an object (approx. 15 cm/6 in. diameter) fastened to an approx. 2 m/80 in. long length of cord is required.

 

 

The object (experience has shown that a ball is suitable) is placed on the relevant seat and the cord is routed outside via the door weatherstrip.

After arming the ATWS and waiting for one minute, pull the object quickly to half way up the window. If the ultrasonic sensor is intact, alarm is triggered.

 

 

This procedure should be repeated for all other ultrasonic sensors.

 

 

Note:

 

The ATWS is at peak sensitivity when the windows and sun roof are completely closed.

 

 

As the TECH 1 data list does not contain a parameter for evaluation of the ultrasonic signal, proceed according to table 4.4.2 in the event of a fault.

 

 

 