vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

CDLS, Table 3, Coding Table,Central Door Locking System Control Unit, Infrared > < CDLS, Explanation of Tables

CDLS, Table 1, ALDL Diagnostic Plug and Voltage Supply, Check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

Test Equipment

Check

Notes

Nominal

Possible Cause of Fault

Step

Multimeter

 

 

 

Value

Trouble-shooting

 

 

MKM-587-A

of

between

 

 

 

 

1

Ohmmeter, range

200 W

Diagnostic plug XD (ALDL); ground

 

XD / Ter. 4

Ground

Ignition OFF

lower than

3 W

Transition resistance at grounding point too high

 

2

Ohmmeter, range

200 W

Diagnostic plug XD (ALDL); ground

 

XD / Ter. 5

Ground

Ignition OFF

lower than

3 W

Transition resistance at grounding point too high

 

3

Voltmeter, range

20 V/DC

Diagnostic plug XD (ALDL); battery voltage

 

XD / Ter. 16

Ground

Ignition OFF

greater than 11 V

Battery voltage absent or battery voltage too low

 

4

Voltmeter, range

20 V/DC

Diagnostic lead to CDLS control unit

XD / Ter. 3

Ground

Ignition ON

greater than 11 V

Carry out test steps 5 and 7

 

If nominal value is attained:

 

Proceed with test step 8

 

 

5

Ohmmeter, range

2 MW

Diagnostic lead to CDLS control unit

XD / Ter. 3

Ground

Ignition OFF

greater than

100 kW

Short circuit to ground

 

Proceed with test step 6

 

 

6

Ohmmeter, range

2 MW

Diagnostic lead to CDLS control unit

XD / Ter. 3

Ground

Disconnect wiring harness plug K37

greater than

100 kW

Short circuit to ground in lead XD / Ter. 3

 

If okay and test step 5 not okay: CDLS control unit defective

 

 

7

Ohmmeter, range

200 W

Diagnostic lead to CDLS control unit passage check

XD / Ter. 3

Wiring har- ness plug K37/ Ter. 8

Ignition OFF

lower than

2 W

Interruption in lead
XD / Ter. 3 to wiring harness plug
K37 / Ter. 3

 

Proceed with test step 8

 

 

8 *)

Voltmeter, range

20 V/DC

Diagnostic lead to CDLS control unit

XD / Ter. 3

Ground

Ignition OFF

 

 

Disconnect wiring harness plug K37

 

lower than

2 V

Short circuit to battery voltage in lea
XD / Ter. 3

 

If okay and test step 4 not okay: CDLS control unit defective

 

9

Ohmmeter,

range

200 W

Ground to CDLS control unit

Wiring har- ness plug K37/ Ter. 19

Ground

 

Ignition OFF

 

 

Disconnect wiring harness plug K37

 

lower than

2 W

No ground to CDLS control unit

 

 

10

Voltmeter, range

20 V/DC

Battery voltage Ter. 30 to CDLS control unit

Wiring har- ness plug K37/ Ter. 15

Ground

 

Ignition OFF

 

 

Disconnect wiring harness plug K37

 

greater than 11 V

Battery voltage Ter. 30 absent at wiring harness plug K37 / Ter. 15

 

 

11

Ohmmeter, range

200 W

Battery voltage Ter. 15 to CDLS control unit

Wiring har- ness plug K37/ Ter. 11

Ground

Ignition ON

 

 

Disconnect wiring harness plug K37

 

greater than 11 V

Battery voltage Ter. 15 absent at wiring harness plug
K37 / Ter. 11

 

 

 

*)    Perform only if no other control units are connected to XD / Ter. 3 (AT, ECSR)

 

 

 