Control Unit, Remove and Install
Remove, Disconnect Shell (glass) - see operation "Shell (Glass), Remove and Install". Moulded headlining - see operation "Moulded Headlining, Remove and Install". Remove water drain hoses (A and B). Notice: For removal and installation of the actuation unit a second mechanic is required.
Install, Connect |
|
Install actuation unit. Notice: If a new actuation unit is installed, the transport holders must removed prior to installation of the drive. |
|
Tighten (Torque) Actuation unit to roof frame - 4 Nm /3 lbf. ft.
Install, Connect Water drain hoses, shell (glass)
Inspect Carry out operation test.
Install, Connect Moulded headlining |
|
|