Exhaust Gas Recirculation Solenoid Valve, Remove and Install
Remove, Disconnect
Remove battery.
Disconnect wiring harness plug (2) and vacuum hoses (1).
Remove exhaust gas re-circulation solenoid valve (3) from bracket on wheel housing.
Install, Connect
Attach exhaust gas re-circulation solenoid valve to bracket on wheel well - tightening torque 4 Nm / 3 lbf. ft.
Attach wiring harness plug and vacuum hoses.
Install battery.