Vectra B
Hot Film Mass Air Flow Meter, Remove and Install Remove, Disconnect
Notice: Before assembling components of the intake system (hoses, connections, etc.), they must be cleaned of any possible contamination (grease, oil, etc.). When tightening the hose clamps, be sure to observe exactly the tightening torque of 3.5 Nm / 2.6 lbf. ft. The arrow on the hot film mass air flow meter indicates the direction of flow of the intake air. Important! It is only ensured that the intake system is free of leaks, thus ensuring operational safety of the engine, if the hose clamps are tightened correctly to the prescribed tightening torque. Install, Connect
|
||||