Install, Connect
Coat new seal rings for injection valves lightly with clean engine oil and attach to fuel distributor pipe with fastening clamp (1) - ensure correct seating.
Carefully press fuel distributor pipe together with injectors into intake bridge - ensure that injectors are correctly seated in intake bridge.
Fasten fuel distributor pipe to intake bridge - 8 Nm / 6 lbf. ft.
Clip wiring trough to fuel distributor pipe and connect insert wiring harness plug to injectors.
Install intake plenum - see operation "Intake Plenum, Remove and Install".