vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Simtec 70|Specifications > < Solenoid Valve - Switchover Valve, Remove and Install (X 18 XE1)

 

Vacuum Unit - Switchover Valve, Remove and Install (X 18 XE1)  

Object Number: 616191  Size: DEFAULT  Remove, Disconnect   

Remove engine control unit - see operation "Engine Control Unit, Remove and Install (X 18 XE1)".  

Unclip actuation rod (1) from switchover valve ball head.  

Detach vacuum hose (2).  

Remove fastening bolts (arrows) and remove switchover valve vacuum unit.  

Object Number: 616192  Size: DEFAULT  Install, Connect   

Attach switchover valve vacuum unit to inlet manifold.  

Attach vacuum hose to vacuum unit.  

Clip actuation rod into ball head.  

Install engine control unit - see operation "Engine Control Unit, Remove and Install (X 18 XE1)".  

Object Number: 2400171  Size: DEFAULT

 

 


Related Literature Units
-

Simtec 70|Specifications > < Solenoid Valve - Switchover Valve, Remove and Install (X 18 XE1)