Blower Motor: Customer Interest
Blower Motor - Inoperative In Extreme Cold

Group: 87 

Number: 02-01

Date: Mar. 4, 2002

Subject:
Fresh Air Blower Motor, Inoperative at Ambient Air 
Temperatures Near or Below Freezing

Model(s): 
New Golf, New Jetta,

1999 --> 2002

New Beetle

1998 --> 2002

Condition

Blower motor -V2-, inoperative during cold temperatures (at or below freezing).

Service

Verify Blower motor operation in climatic conditions at or below freezing (prior to moving vehicle into workshop).

Note:

Check condition quickly once vehicle is in the workshop the warmer temperatures may eliminate condition.

If Blower motor is inoperative:

-

Verify power and ground supply to motor. If power and ground to motor are OK:

-

Remove blower motor see VESIS Repair Group 80 - "Heating and ventilation system, servicing"

With blower motor removed:

-

Visually inspect for ice or moisture build-up on commutator bars of motor armature through cut-out in blower motor housing.

If evidence of ice or moisture tracking are present:

-

Install new blower motor Part No:
1J1 819 0210 see VESIS Repair Group 80 - "Heating and ventilation system, servicing"