Page 24
background image

-

Fuse 43 must be OK

-

The battery voltage must be at least 11.5 V

-

Fuel pump relay must be OK

Test sequence

-

Connect scan tool VAG 1551 (VAG 1552). Start engine and select "Address word" 01 of engine control module. When doing this the engine must
be running at idle speed. Connecting scan tool and selecting engine control module. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial
Checks/VAG 1551 Scan Tool", See: Testing and Inspection 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press keys 0 and 8 for the function "Read measuring value block" and confirm entry with Q key.

Indicated on display

Read measuring value block 
Input display group number XXX

-

Press keys 0, 4 and 1 for "Display group number 41" and confirm entry with Q key.

Indicated on display (1-4 = Display zones)

Read measuring value block 41

->

1

2

3

4

-

Check status of HO2S in display field 2.

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 4059 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 4057