volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1279 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1277
Page 3
background image

If the specification is obtained:

-

Change to display group 36 as follows:

-

Press C key.

-

Press keys 0, 3 and 6 for "Display group number 36" and confirm entry with Q key.

Indicated on display (1-4 = Display zones)

System in basic setting 36

->

4

-

Check the oxygen sensor voltage in display zone 1.

-

Allow engine to run at an increased speed until:
Specification: "B1-S2 OK." appears in display zone 4.

If the diagnostic is initiated from engine control module the display in display zone 4 jumps from "Test OFF" to "Test ON."

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1279 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1277