volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1291 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1289
Page 6
background image

-

The slots or holes in probe body are blocked

-

The probe vent hole in area of connecting wire is blocked

-

The probe has been overheated (glazed)

-

The probe has been damaged by leaded fuel

Checking oxygen sensor wiring for HO2S -G39-

-

Remove inner plenum chamber cover, left:

-

Connect test box VAG 1598/31 to control module wiring harness. The engine control module is not connected by this action.

-

Remove protective cover -arrows- and separate 6-pin connector (black) -1- to oxygen sensor before catalyst -G39-.

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1291 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 1289