volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Recall - Oxygen Sensor Replacement/ECM Software Update|Page 3764 > < Recall - Oxygen Sensor Replacement/ECM Software Update|Page 3762
Page 6
background image

Owner Letter

Section A

SECTION A- ECM Fault Interrogation

-

Ignition switch in "OFF" position

-

Obtain VAS 5051 and switch "ON"
-

Connect VAS 5051 / 6 diagnostic cable to data link connector located under dash on left side -arrow-

-

Turn ignition switch to "ON" position

-

On VAS 5051 Start-up screen, press "Vehicle Self- Diagnosis" button -arrow-

-

Select "01 - Engine Electronics"

-

Select "02 - Interrogate fault memory"

-

If DTC is present for the front oxygen sensor, print DTC information, turn ignition switch to "OFF" position, disconnect VAS 5051 from vehicle
and proceed to SECTION B