NOTE:  DTC print-out must remain with dealerships repair order copy.

-

If no front oxygen sensor DTC is present, turn ignition switch to "OFF" position and go to SECTION C

Section B

SECTION B - Front Oxygen Sensor Replacement

-

Disconnect wire harness connector from oxygen sensor
-

Use special tool 3337 to remove front oxygen sensor -1- from exhaust manifold

NOTE:  Coat threads of new oxygen sensor, 06A 906 262 Q, using anti-seize compound not containing silicon and marked  safe for oxygen
sensors . Do not allow compound to enter slots on sensor body

-

Install new oxygen sensor (06A 906 262 Q) and tighten to 50 Nm (37 ft. lbs.)

-

Reconnect oxygen sensor to wire harness

-

Proceed to SECTION C

Section C

SECTION C - ECM Reprogramming

-

Disconnect VAS 5051/6 cable from vehicle

-

Press "Go To" button on VAS 5051

-

Select "Exit"
-

Insert CD ROM, 1J0 909 961, into VAS 5051 -arrow-

NOTE:  To ensure work completion, VAS 5051 must be connected to a 110V supply, before VAS 5051 internal battery loses required voltage

-

VAS 5051 Start-up screen: press "Applications" button -arrow-

-

Step-by-step instructions for reprogramming ECM will follow