Page 11
background image

-

Press (<) button when "ADP. O.K." is on screen

-

Start engine and let idle

-

Press buttons -7- & -7- for Display Group 77: Secondary Air Check

-

Press "Q" button to confirm

NOTE:  Test may not start until temperature (on screen) reaches approx. 76.5°C

-

Press (<) button when "Syst. OK" is on screen

-

Press buttons -7- & -0- for Display Group 70: EVAP System

-

Press "Q" button to confirm

NOTE:  Test may not start until temperature (on screen) reaches approx. 76.5°C

-

Press (<) button when "TBV OK" is on screen

-

Press buttons -7- & -1- for Display Group 71: Leak Test EVAP System

-

Press "Q" button to confirm

-

Press (<) button when Syst. OK is on screen

-

Press buttons -3- & -4- for Display Group 34: Oxygen Sensor Aging

-

Press "Q" button to confirm

-

Using VAG 1788/10 set engine speed to 2200 - 2800 RPM

NOTE:  Test may not start until temperature (on screen) is higher than 352.0°C

-

Press (<) button when B1-P1. OK is on screen

-

Press buttons -4- & -6- for Display Group 46: Catalytic Converter

-

Press "Q" button to confirm

-

Using VAG 1788/10 set engine speed to 2800 - 3200 RPM

Note: Test may not start until temperature (on screen) is higher than 352.0°C

-

Press (<) button when Cat "B1 OK" is on screen

-

Remove VAG 1788/10 from vehicle to bring engine down to idle

-

Press (<) button two times

-

Select "15 - Check readiness code"

-

Readiness code should read 00000000

-

Press "Print" button for copy to attach to repair order

-

Press (<) button

-

If vehicle has automatic transmission, turn ignition switch to "OFF" position, press (<) button and proceed to Section F, otherwise go to next step

-

Select "06 - End Output"

-

Switch ignition to "OFF" position

NOTE:  The coding values entered and shown on the display will not be used by the Motronic Control Module UNTIL the ignition has been
switched OFF once

-

Disconnect VAS 5051 / 6 diagnostic cable harness from data link connector

-

Remove CD ROM from VAS 5051 vehicle diagnostic tester

Section F

Section F - Automatic Transmission - Initiating Basic Settings

-

Turn ignition switch to "ON" position

-

Select "02 - Gearbox Electronics"

-

Select "02 - Interrogate fault memory"

-

Press (<) button

-

Select "05 - Erase fault memory", if required

-

Press "OK " button

-

Press (<) button, if faults erased

-

Select "04 - Initiating Basic Settings"

-

Press -0- button for Display Group 0: Basic Setting

-

Press "Q" button to confirm

-

Depress accelerator pedal as far as kick down and hold in this position for 3 seconds

-

Press (<) button

-

Select "06 - Exit program"

-

Release accelerator pedal

-

Switch ignition to "OFF" position

Recall - Oxygen Sensor Replacement/ECM Software Update|Page 4178 > < Recall - Oxygen Sensor Replacement/ECM Software Update|Page 4176