Beetle L4-2.0L (AEG) (2000)
Fuel Pump Check Valve: Testing and Inspection
With Generic Scan Tool
Fuel Pump (FP) Check-Valve, Checking
Test requirements
-
Remote control is still connected.
-
Pressure gauge is still connected.
Test sequence
NOTE: This test also checks the connections of the fuel supply line from Fuel Pump (FP) to connection point of V.A.G 1318 pressure gauge for proper
seal.
-
Close pressure gauge shut-off valve (lever perpendicular to direction of flow -position B-).
-
Operate remote control in short intervals until a positive pressure of approx. 3 bar has built up.
-
If excess pressure is built up, reduce pressure by carefully opening shut-off valve.
WARNING: Danger of spray when opening shut-off valve. Hold container in front of open connection on pressure gauge.
-
Observe pressure drop on pressure gauge. Pressure must not fall below 2.5 bar within 10 minutes.
If pressure drops further:
-
Check line connections for proper seal.
If no malfunctions are found in wires:
-
Fuel Pump (FP) faulty, replace Fuel Pump (FP) unit, Fuel Pump (FP) unit, removing and installing.
-
Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.
-
Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes