Fuel Pump Check Valve: Testing and Inspection
With Generic Scan Tool

Fuel Pump (FP) Check-Valve, Checking

Test requirements

-

Remote control is still connected.

-

Pressure gauge is still connected.

Test sequence

NOTE:  This test also checks the connections of the fuel supply line from Fuel Pump (FP) to connection point of V.A.G 1318 pressure gauge for proper
seal.

-

Close pressure gauge shut-off valve (lever perpendicular to direction of flow -position B-).

-

Operate remote control in short intervals until a positive pressure of approx. 3 bar has built up.

-

If excess pressure is built up, reduce pressure by carefully opening shut-off valve.

WARNING:  Danger of spray when opening shut-off valve. Hold container in front of open connection on pressure gauge.

-

Observe pressure drop on pressure gauge. Pressure must not fall below 2.5 bar within 10 minutes.

If pressure drops further:

-

Check line connections for proper seal.

If no malfunctions are found in wires:

-

Fuel Pump (FP) faulty, replace Fuel Pump (FP) unit, Fuel Pump (FP) unit, removing and installing.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  

-

Generate readiness code.  See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes