Basic voltage checking

-

Remove protective cover -arrows- and disconnect black 4-pin harness connector to Oxygen sensor G39 (before Three Way Catalyst).

-

Switch Fluke 83 multimeter to Voltage range

-

Connect Fluke 83 multimeter between ECM harness connector terminals 3 + 4 using jumper wires from VW 1594 adaptor kit.