Check wires between test box and 4-pin connector (to control module) for open circuit according to wiring diagram.
-

Terminal 3 + socket 51

-

Terminal 4 + socket 52

-

Wire resistance: max. 1.5 Ohms

Vehicles with engine code AVH, AZG, BDC

-

Check wires between test box and 4-pin connector (to control module) for open circuit according to wiring diagram.
-

Terminal 3 + socket 68

-

Terminal 4 + socket 69

-

Wire resistance: max. 1.5 Ohms

Continuation for all vehicles

-

Also check wires for short circuit to B+ and Ground (GND). Specified value: Infinite Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer Scan Tool

Oxygen Sensor and Oxygen Sensor Control After Three Way Catalyst, Checking

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551/1552 Scan Tool using VAG 1551/3 Adaptor cable

-

VAG 1598/22 Test Box

-

Fluke 83 multimeter

-

VW 1594 Adaptor kit

-

Wiring diagram

Requirements

-

Engine Control Module MUST be matched to the Throttle Control Module. 

-

Exhaust system between Three Way Catalyst and cylinder head must be free of leaks

-

Engine Coolant Temperature must be 85 °C minimum See Display group 04, Display field 3.

Functional check

-

Connect VAG 1551/1552 Scan Tool. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks", See: Computers and Control