volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Aging, Check|Page 3094 > < Oxygen Sensor Aging, Check|Page 3092
Page 4
background image

-

Fuse 43 must be OK.

-

Battery Voltage must be 11.5 Volts minimum

-

Fuel pump relay must be OK

Test sequence

-

Connect VAG 1551/1552 Scan Tool. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks" See: Computers and Control
Systems/Testing and Inspection 

-

Start engine and let idle.

-

Press 0 and 1 buttons to select "Engine Electronics" address word 01.

Indicated on display (example only)

06A906018AB Motronic M5.9.2 HS V06

->

Coding 00000

WSC 00000

-

Press -> button.

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press 0 and 8 buttons to select "Read Measuring Value Block" function 08.

-

Press Q button to enter input.

Indicated on display

Read measuring value block
Input Display group number XXX

-

Press 0, 4 and 1 buttons to select "Display group 41"

-

Press Q button to enter input.

Indicated on display (1 to 4 = Display fields)

Read measuring value block 41

->

1

2

3

4

-

Observe resistance in Display field 1 for Oxygen sensor heater before Three Way Catalyst.