9

NC hose bracket

10

10 Nm (7 ft lb)

11

25 Nm (18 ft lb)

12

Secondary Air Injection pump motor
-

Checking:

See Below.

13

Secondary Air Injection pump intake hose

14

to Air Cleaner

15

to exhaust manifold union

16

30 Nm (22 ft lb)

17

Connector tube

18

10 Nm (7 ft lb)

19

10 Nm (7 ft lb)

20

Pneumatic-valve connector housing

21

25 Nm (18 ft lb)

22

Gasket
-

Replace

23

Union

Pneumatic-valve, Checking

Special Tools, Testers And Auxiliary Items

-

 US 8026 Hand Vacuum Pump

Test Sequence

-

Disconnect vacuum hose from Secondary Air Injection solenoid valve

-

Attach US 8026 hand vacuum pump to vacuum hose

-

Disconnect pressure line from Pneumatic-valve

NOTE:  Do Not Use Compressed Air For The Following Check.

-

Connect auxiliary hose to Pneumatic-valve and blow into it.
-

Pneumatic-valve must be closed.

-

Operate hand vacuum pump.
-

Valve must open and operate smoothly (without sticking).

-

Replace valve if necessary.

Secondary Air Injection pump motor, checking

Special tools

-

VAG 1598/18 Test Box

-

VW 1594 connector test kit

-

VAG 1527B Voltage Tester

Checking requirement

-

Secondary Air Injection pump relay fuse OK

Checking sequence

-

Switch OFF ignition

-

Connect VAG 1598/18 Test Box to ECM wiring harness.

-

Disconnect pressure line from Pneumatic-valve.

-

Switch ON ignition.

-

Bridge Test Box sockets 01 + 06 using jumper wires from VW 1594 adaptor kit.