Cabrio GLX L4-2.0L (ABA) (2001)
-
Check probe heating for continuity at Oxygen sensor connector contacts 1 and 2.
If it is determined that probe heating has an open circuit:
-
Replace Heated oxygen sensor (HO2S) before catalytic converter - G39-.
If probe heating has continuity:
-
Set multimeter to measure voltage and connect to contacts 1 and 2 on connector to control module.
-
Start engine and run at idle speed.
-
Measure voltage supply:
-
When display group 41, display zone 2 displays:
Htg.bC.ON:
Specification: 11.0 to 14.5 V
Display: Htg. bC.ON/Htg.bC.OFF (alternating)
Specification: Between 0.0 to 12.0 V fluctuating switch ignition off.
If no voltage is present:
-
Connect test box VAG 1598/22 to control module wiring harness.