volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1261 > < Diagram Information and Instructions|Page 1258
Page 1
background image

Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking

Heated Oxygen Sensor (HO2S) -G39- For Oxygen Sensor Before Three Way Catalytic (TWC) Converter, Checking

Special tools and equipment

-

Scan tool VAG 1551 or VAG 1552 with cable VAG 1551/3

-

Test box VAG 1598/22

-

Hand multimeter VAG 1526 or multimeter VAG 1715

-

Adapter set VAG 1594

-

Wiring diagram

Check conditions

-

The battery voltage must be at least 11.5 V

-

Fuel pump relay must be OK

Test sequence

-

Connect VAG 1551 Scan Tool ((VAG 1552). Start engine and select "Address word" 01 of engine control module. When doing this the engine
must be running at idle speed. (Connecting scan tool and selecting engine control module See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan
Tool/Connecting VAG Scan Tool 1551/1552).

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press keys 0 and 8 for function "Read Measuring Value Block" and confirm entry with Q key.

Indicated on display

Read Measuring Value Block

HELP

Input display group number

XXX

-

Press keys 0, 4 and 1 for "Display group number 41" and confirm entry with Q key.

Indicated on display: (1 to 4 Display zones)

Read Measuring Value Block 41

->

1

2

3

4

-

Check Oxygen sensor heater resistance in display zone 1
Specification: 6.4 to 47.5 Ohm

-

Check status of Heated Oxygen Sensor (HO2S) in display zone 2:
Display: Htg.bC.ON

NOTE:  The Heated Oxygen Sensor (HO2S) may be switched on or off depending on the operating mode of the engine, therefore the display in display
zone 2 may show "Htg.bC.ON or alternating from Htg.bC.ON to Htg.bC.OFF.

If the specifications are not attained:

Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1261 > < Diagram Information and Instructions|Page 1258