Corrado L4-1781cc 1.8L SOHC SC (PG) (1990)
Ignition Hall Effect Sensor: Testing and Inspection
Checking
Hall sender unit, checking
Requirement
-
Electrical check of Digifant system OK
Voltage supply, checking
remove harness connector from Hall sender (on distributor)
- switch multimeter US 1119 to 20 volt range
- connect multimeter to outer terminals of harness connector
- switch ON ignition
-
10 volts minimum
If less than 10 volts
- replace Digifant control unit
If zero volts
- locate and eliminate open circuit in wiring using wiring diagram