background image

-

Disconnect the ventilation hoses - 1 and 2 - and pull the Evaporative Emission (EVAP) canister - A - with the hoses upward out of the bracket.

CAUTION!
Hot steam may escape when opening the expansion tank cap. Wear protective goggles and protective clothing to prevent damage to eyes
and scalding. Cover the cap with a cloth and open very carefully. 

-

Open and close the coolant expansion tank cap to reduce the pressure.

-

Loosen the clamp - arrow - and disconnect the coolant hose. Collect any leaking coolant with a cloth.

-

Disconnect the connector - 1 - from the expansion tank. Loosen the bolts and lay it on its side.