Eos (1F7) L4-2.0L Turbo (BPY) (2007)
If any of the specifications are not obtained:
-
Replace the Leak Detection Pump (LDP) (-V144- ).
If the specified values are obtained:
Checking voltage supply
‹› The voltage for the Leak Detection Pump (LDP) (-V144- ) is supplied by the Engine Control Module (ECM) (J623).
-
Check the Leak Detection Pump (LDP) (-V144-) for voltage.
-
Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-)electrical harness connector terminal 3 for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
-
Switch the ignition off.
If the specified value was not obtained: