Connect a fuel line from the High pressure fuel gauge to the disconnected fuel return line and hold it in the measuring container.

CAUTION!
Danger of spraying when opening shut-off valve; wear protective goggles and protective clothing to prevent injuries and contact with
skin. Hold container in front of open connection of pressure measuring device.

-

Close the shut-off valve of High pressure fuel gauge. 

-

Press switch on the Hand held remote control (jumper) while opening the shut-off valve slowly until 4 bar positive pressure is indicated on
pressure gauge. Do not change position of the shut-off valve. 

-

Empty into the measuring container.

Delivery rate of the fuel pump is dependent on the battery voltage. 

-

Operate the remote control for 30 seconds.

-

 Using a Multimeter, check battery voltage while the fuel pump is running.

-

Compare the fuel quantity pumped with the specified value.