Eos (1F7) L4-2.0L Turbo (BPY) (2007)
‹› The mm specifications apply to the value read out (includes 1 mm preload).
-
Release pressure via (VAS 6342) to 0 mbar.
-
Set the (VAS 6341/1) to 0.
‹› The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.
-
Operate the (VAS 6213) until the (V.A.G 1397A) displays 350 +/-5 mbar.
-
Read and make a not of the value on the (VAS 6341/1).
-
Operate the (VAS 6213) until the (V.A.G 1397A) displays 650 to 700 mbar.
-
Release the pressure via the (VAS 6342) to 350 +/- 5 mbar.
-
Read and make a not of the value on the (VAS 6341/1).
-
Add values 1 and 2 and divide by 2.
-
The result (mean value) must be 5 +/- 0.25 mm.
-
If the result (mean value) is not 5 +/- 0.25 mm, correct the adjustment, tighten the lock nut by hand and repeat the measurement.
-
If the result (mean value) is 5 +/- 0.25 mm, tighten the lock nut to 5 Nm and secure with sealing wax.
-
Secure the securing plate above linkage of the vacuum diaphragm.