volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Wastegate Actuator|Testing and Inspection|Page 8030 > < Wastegate Actuator|Testing and Inspection|Page 8028
Page 4
background image

‹› The mm specifications apply to the value read out (includes 1 mm preload).

-

Release pressure via (VAS 6342) to 0 mbar.

-

Set the (VAS 6341/1) to 0.

‹› The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.

-

Operate the (VAS 6213) until the (V.A.G 1397A) displays 350 +/-5 mbar.

-

Read and make a not of the value on the (VAS 6341/1).

-

Operate the (VAS 6213) until the (V.A.G 1397A) displays 650 to 700 mbar.

-

Release the pressure via the (VAS 6342) to 350 +/- 5 mbar.

-

Read and make a not of the value on the (VAS 6341/1).

-

Add values 1 and 2 and divide by 2.

-

The result (mean value) must be 5 +/- 0.25 mm.

-

If the result (mean value) is not 5 +/- 0.25 mm, correct the adjustment, tighten the lock nut by hand and repeat the measurement.

-

If the result (mean value) is 5 +/- 0.25 mm, tighten the lock nut to 5 Nm and secure with sealing wax.

-

Secure the securing plate above linkage of the vacuum diaphragm. 

Wastegate Actuator|Testing and Inspection|Page 8030 > < Wastegate Actuator|Testing and Inspection|Page 8028