If indication jumps to approx. 140° C:

-

End diagnosis and switch ignition off.

-

Replace the Intake Air Temperature (IAT) Sensor ( G42).

If indication remains at approx. -40° C or -46° C:

°Testing if display approx. 140 C:

-

Disconnect the Intake Air Temperature (IAT) Sensor (G42) electrical harness connector - arrow -. 

If indication jumps to approx. -40° C or -46° C:

-

End diagnosis and switch ignition off.

-

Replace the Intake Air Temperature (IAT) Sensor ( G42).

If the indication remains at approx. 140° C:

Checking wiring

Add as a workstep to the procedure where required.

If the manufacturers test box is being used. Perform the following step.

-

Install the Test Box 105 Pin (VAG1598/42).

If the manufacturers test box is not being used. Perform the following step.