Eos (1F7) L4-2.0L Turbo (BPY) (2007)
Front Door Window Regulator: Testing and Inspection
Window Regulator Basic Setting
NOTE:
-
Window regulator motor must operate with greatest possible operating force for window regulator basic setting. Therefore, it is necessary to leave
the engine running.
-
The window regulator basic setting is performed with door open but latch closed.
Procedure for window regulator basic setting:
-
Start engine.
-
Open door and close latch in door lock.
-
Lower door window completely.
-
Close door window and block with hand. Door window lowers (reverses).
-
Close door window again within 5 seconds and block with hand again. The door window stops.
-
Close door window again within 5 seconds. Door window runs without pinch protection up to mechanical window regulator stop.
-
Within 5 seconds, hold window regulator switch for 5 seconds. Now window regulator motor is adjusted to window regulator.
-
Open latch in door lock, door window lowers in short lift.
-
Close door, door window closes.
The following 4 door window to roof pillar seal positions are possible:
-
The door window runs into seal between markings. Door window adjustment is correct.
-
Door window does not run up to upper marking. Door window must be corrected in height adjustment toward top
-
Door window runs further into seal as far as lower marking. Door window must be corrected in height adjustment toward bottom
-
Door window runs into seal and lowers again. Door window must be corrected in height adjustment toward bottom. Perform basic setting again
after successful correction.