Eos (1F7) V6-3.2L (BUB) (2008)
Condenser HVAC: Service and Repair
Condenser
Special tools, testers and auxiliary items required
‹› A/C service station (VAS 6007A)
‹› Refrigerant must be extracted before hand using e.g. A/C service station (VAS 6007A).
‹› The previously used service stations can still be used.
‹› To prevent the ingress of dampness all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
Perform following work first:
-
Switch off all electrical consumers.
-
Switch off ignition.
-
Remove ignition key.
-
Extract refrigerant e.g. using A/C service station (VAS 6007A).
‹› Environmentally hazardous draining of refrigerant is an offense punishable by law.
-
Remove the bumper.
-
Remove lock carrier.
-
Remove the refrigerant lines on the condenser, loosen (12 ± 1 Nm) and seal off.