Oxygen Sensor: Testing and Inspection
Functions, Checking

Heated Oxygen Sensors G39 and G108, Checking

Heated Oxygen Sensors G39 and G108, Checking

The following procedure is used to diagnose both Heated Oxygen Sensor (HO2S) (G39) and Heated Oxygen Sensor (HO2S) 2 (G108)

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connectors of the Heated Oxygen Sensor (HO2S) ( G39) and

Heated Oxygen Sensor (HO2S) 2 (G108).

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor (O2S) 2 Heater (Z28) fuses OK.

‹› The Oxygen Sensor (O2S) Heater (Z19) and Oxygen Sensor (O2S) 2 Heater (Z28) before catalytic converter OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80° C.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check

Start diagnosis

Function test

-

Connect scan tool.

-

Start the engine and let it run at idle.

-

Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

-

Select "Test-ID 01: Oxygen sensor monitoring before catalytic converter".

-

Select "Test-ID 131: Dynamic test".

-

Check the specified values at idle.

If specified values are obtained:

Functions, Checking|Page 3025 > < Engine Controls - Silicone Sealer/Lubricant Precautions