Eos (1F7) V6-3.2L (BUB) (2008)
If the specified value was not obtained:
-
Using a Multimeter, check the Secondary Air Injection (AIR) Pump Motor (V101) electrical harness connector terminal 2 to Ground (GND).
Specified value: battery voltage.
If the specified value was not obtained:
-
Check the wiring connection from the Secondary Air Injection (AIR) Pump Relay (J299) socket 2/87 to the Secondary Air Injection (AIR) Pump
Motor (V101) electrical harness connector terminal 2 for an open circuit or a short circuit.
-
Check the wiring connections for damage, corrosion, lose or broken terminals.
-
If necessary, repair the faulty wiring connection.
If the specified value was obtained:
Checking Ground (GND)
-
Using a Multimeter, check the Secondary Air Injection (AIR) Pump Motor (V101) electrical harness connector terminal 1 to Ground (GND) for
resistance.
Specified value: 1.5 ohms Max.
If the specification was not obtained:
-
Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).