Eos (1F7) V6-3.2L (BUB) (2008)
If the specified value was not obtained:
-
Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
If the specified value was not obtained:
-
Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector terminal
1 to the Power Supply Relay (terminal 30, B+) (J317) terminal 2/87 for an open circuit according to wiring diagram.
If the specified value was not obtained:
-
Check the wiring for a short circuit to Battery positive (+) or an open circuit.
-
Check the electrical harness connector for damage, corrosion, lose or broken terminals.
-
If necessary, repair the wiring connection.
If the specified value was obtained:
Check Ground (GND) activation
-
Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector to Battery
positive (+) for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
-
Switch the ignition off.
If the specified value was not obtained: