Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3149 > < Leak Detection Pump, Evaporative System|Testing and Inspection
Page 2
background image

If the specifications was not obtained:

-

Replace the Leak Detection Pump (LDP) (-V144- ).

If the specified values are obtained:

Checking voltage supply

‹› The voltage for the Leak Detection Pump (LDP) (-V144- ) is supplied via the Power Supply Relay (terminal 30, B+) (J317).

-

Check the Leak Detection Pump (LDP) (-V144-) for voltage.

-

Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 to Ground (GND) for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3149 > < Leak Detection Pump, Evaporative System|Testing and Inspection