volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Functions, Checking|Page 2604 > < Functions, Checking|Page 2602
Page 5
background image

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

Function test

-

Connect scan tool.

-

Start the engine and let it run at idle.

-

Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

-

Select "Test-ID 02: Oxygen sensor monitoring behind catalytic converter".

-

Select following Test-IDs.

-

Check the specified values at idle.

If the specified values are obtained:

-

End diagnosis and switch ignition off.

If the specified values are not obtained:

-

Remove the right vehicle floor cover - arrows -. 

Checking primary voltage

-

Disconnect the brown Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  1 - or Oxygen
Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) - 2 -.

Functions, Checking|Page 2604 > < Functions, Checking|Page 2602