Eurovan V6-2800cc 2.8L (AES) (2000)
If warning lamp lights up when ignition is switched on:
-
Start engine and let run at idle:
Warning lamp must go out after a few seconds.
If the warning lamp does not go out:
-
Switch ignition off.
-
Remove instrument cluster.
-
Check wire connection between Engine Control Module (ECM) and instrument cluster for short circuit to Ground (GND) according to wiring
diagram.
-
Erase DTC memory of Engine Control Module (ECM). See: Testing and Inspection
-
Generate readiness code. See: Testing and Inspection
If no malfunctions are detected in wire from Engine Control Module (ECM) to warning lamp:
-
Replace Motronic Engine Control Module (ECM) -J220-.