Eurovan V6-2800cc 2.8L (AES) (2000)
Air Injection Bypass Valve: Testing and Inspection
Special tools, testers and auxiliary items
8012 Hand vacuum pump (illustration shows V.A.G 1390)
Checking conditions:
Vacuum pipes and hose connections free of leaks.
-
Vacuum lines not blocked-kinked.
-
Remove sound dampening tray.
-
Disconnect vacuum hose from combi-valve from Secondary Air Injection solenoid valve N112.
Connect US 8012 hand vacuum pump to combi-valve vacuum hose arrow->.
NOTE: Do not use compressed air during the following check!
Detach hose to combi valve at Air Cleaner upper section arrow-> and pressurize slightly by blowing into hose.
-
combi-valve must be closed.
-
Operate hand vacuum pump.
-
combi-valve must open.
-
If combi-valve does not open.
-
Replace combi-valve.