volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3187 > < Functional Check|Page 3183
Page 1
background image

Leak Detection Pump: Testing and Inspection

Leak Detection Pump (LDP), Checking

Special tools and equipment

-

Fluke 83 Multimeter

-

VAG 1527 B Voltage tester

-

VW 1594 Adaptor kit

-

Wiring diagram

Function test

-

Initiate Output Diagnostic Test Mode (DTM) and select EVAP Canister Purge Solenoid Valve -N115-

During DTM, Control Module for Fuel System Diagnosis -J490- and Leak Detection Pump (LDP) are triggered. By touching LDP you can feel whether
the pump works.

Electrical test

-

Disconnect 3-pin connector -1- from LDP.

-

Switch Fluke 83 multimeter to resistance range.

-

Connect multimeter between terminals 1 and 3 of LDP.
-

Specification: 640 to 720 Ohms

-

Connect multimeter between terminals 2 and 3 of LDP.
-

Specification: 17.5 to 27.5 Ohms.

If specifications not obtained:

-

Replace Leak Detection Pump -V144-.

Voltage supply, checking

Requirement

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3187 > < Functional Check|Page 3183