Eurovan V6-2800cc 2.8L (AES) (2000)
-
Connect multimeter to terminals 1 + 2 on Oxygen sensor connector using jumper wires from VW 1594 adapter kit.
-
Measure resistance.
-
specification: 0.00 to 24.2 Ohms
If specification not obtained:
-
Replace -G108- Oxygen sensor (after cat).
If specification obtained:
-
Switch multimeter to 20 Volt DC range.
-
Connect multimeter between terminals 1 + 2 of ECM connector using jumper wires from VW 1594 kit.
-
Measure Voltage supply when display group 121, Display field 4, 1st position from left = 1.
-
specification: 11.0 to 14.5 Volts
Measure Voltage supply when display group 121, Display field 4, 1st position from left = alternating 0 and 1
-
specification: between 0.0 and 12.0 Volts and fluctuating
If no Voltage present:
-
Connect multimeter between terminal 1 of ECM connector and Ground using jumper wires from VW 1594 adapter kit
-
specification: 11.0 to 14.5 Volts
If no Voltage present again:
-
Check wiring between terminal 1 and fuse/relay panel using wiring diagram.
If Voltage present: