Eurovan V6-2800cc 2.8L (AES) (2000)
Air Cleaner Housing: Service and Repair
Air Cleaner, Removing and Installing
1
-
Rubber mounting
2
-
Air Cleaner upper section
3
-
Filter element
4
-
O-ring
-
replace if damaged
5
-
Intake hose
-
ensure it is seated tightly
-
to Secondary Air Injection Pump Motor V101.
6
-
4-pin harness connector
-
black
-
for Mass Air Flow sensor G70
7
-
Mass Air Flow sensor G70*
-
checking: See 'Computers and Control Systems, Air Flow Meter.' See: Computers and Control Systems/Air Flow Meter/Sensor/Testing
and Inspection
8
-
Intake hose
-
ensure it is tightly seated
9
-
Vacuum hose
-
to junction piece for EGR valve /intake manifold
10
-
Positive Crankcase Ventilation Heater Element N79
-
for PCV valve
-
arrow on heater element points toward intake hose
-
resistance specification at ambient temperature (approx. 25 °C) : 7 to 12 Ohms
11
-
Positive Crankcase Vent valve
-
arrow on crankcase breather valve points to intake hose
-
from cylinder head
12
-
Connecting hose
13
-
2-pin harness connector
-
black
-
for heater element N79
-
check heater element Voltage supply between terminals 1 and 2, with ignition switched ON : 11.5 Volts minimum
14
-
Connecting hose
-
from connection on lower intake manifold.