NOTE:

-

The following procedure only applies to batteries without charge indicator.

-

In order to better determine a battery's overall condition, it is recommended to perform always the electrolyte specific gravity test in conjunction
with the load test. See:  

WARNING!

-

Before working with electrolyte, refer to Warnings and Safety Measures.

-

Dispose of electrolyte (sulfuric acid) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to
local regulations pertaining to electrolyte disposal.

-

The following notes and procedures must be followed to ensure correct measurements.

Special tools, testers and auxiliary items

-

Commercially available hydrometer

-

Shop rags

NOTE:

-

Minimum battery temperature of 10 °C (50 °F) is required when carrying out specific gravity tests.

-

Specific gravity of all cells must be checked.

-

Switch ignition off

-

Remove all battery cell caps.