Evaporator Drain Tube: Testing and Inspection
With an otherwise properly operating A/C system, water sprays out of instrument panel vents
-
Check evaporator drain pipe for proper routing (should not be kinked or pinched).
-
Check evaporator water drain valve.
-
Must not be plugged with wax, dirt or undercoating (clean if necessary).
-
Valve flap must open/close properly.
-
Check plenum tray.
-