Eurovan MV V6-28L (AXK) (2002) Odometer Service and Repair
The km reading entered is now indicated on the instrument cluster display. If the km reading indicated is not OK or was entered incorrectly:
-
Press -C- button and repeat input of correct adaptation value
If the km reading indicated is OK:
-
Press -Q- button to confirm input.
Indicated on display:
Channel 9 adaptation 8963
Q
Store modified value?
-
Press -Q- button to confirm input.
Indicated on display:
Channel 9 adaptation 8963
->
Modified value has been stored
-
End adaptation of the odometer by pressing -> button.
Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -6- to select function 06 "End Output",
Indicated on display:
Rapid data transfer
Q
06 - End Output
-
Press -Q- button to confirm input.
Indicated on display:
Rapid data transfer
HELP
Enter address word XX
-
Switch off ignition.
-
Disconnect Data Link Connector (DLC)
Distance impulse number (K number), reading
NOTE:
-
The distance impulse number is a constant value that is required for calculating the speed indication and the distance traveled.
-
The distance impulse number (K number) cannot be changed via the "adaptation" function!
-
For instrument clusters with mile indicators, the distance impulse number is shown in kilometers. The trip impulse number for mile values can be
calculated as follows: Trip impulse number for kilometer values x 1.609 See trip impulse number for mile values.
-
Press the -C- button on the VAG 1551 to abort the "Read distance impulse number" function.
-
Connect VAG 1551 Scan Tool (ST), select operating mode 1 "Rapid data transfer", switch ignition on and enter address word 17 for "instrument
cluster".
After control module identification is displayed:
-
Press -> button.
Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -1- and -0- to select function 10 "Adaptation".