Eurovan MV V6-2.8L (AXK) (2002)
-
Check status of oxygen sensor control behind Three Way Catalytic (TWC) Converter (display field 2): Specification: 1 1 0
NOTE: The bits in display fields 2 are only set to 1 behind Three Way Catalytic (TWC) Converter temperature has risen to above 350 °C and the
Engine Control Module (ECM) has recognized a partial throttle signal (See display group 43, display field 2).
Explanation of 3-digit value in display field 2:
-
Display Group 30 and its evaluation
If oxygen sensor heater is not active, that is if it stays at 0:
-
Test oxygen sensor heater behind Three Way Catalytic (TWC) Converter. See: Heater Check
If oxygen sensor or oxygen sensor control behind Three Way Catalytic (TWC) Converter is not active:
Checking primary voltage
-
Disconnect 4-pin harness connector (arrow) to Oxygen Sensor (O2S) behind Three Way Catalytic (TWC) Converter -G130- behind Three Way
Catalytic (TWC) Converter (bank 1).