Connect multimeter to the following' connector terminals for voltage measurement.
Terminal 1 + Ground (GND)
Terminal 1 + 5
Terminal 2 + Ground (GND)
Terminal 2 + 3
Specification: at least 4.5 V
-
Switch ignition off.
If specified values are not obtained:
-
Connect VAG1598/31 test box to control module wiring harness. Engine Control Module (ECM) is not connected.