Eurovan MV V6-2.8L (AXK) (2002)
-
Remove (red) connector block -arrow- (for relay position 3) on reverse side of lower relay carrier
-
Remove terminal from position number 3 -arrow- of red connector block
-
Insert this terminal -3- into connector housing -11A- (191 972 751 or 1J0 972 751)
NOTE: The terminal housing 1J0 972 751 comes with the wiring harness assembly
IMPORTANT: To insert terminal -3- into the 1J0 972 751 housing, the side clip needs to be opened
-
Connect the housing -11A- to the connector housing -4- on the new harness assembly
-
Locate terminal -3A- (arrow) [short wire from connector housing -4-] on new harness assembly