Eurovan MV V6-2.8L (AXK) (2002)
-
Set multimeter for resistance measurement and check resistance of sensor heating between terminals 1 + 2 at connector for oxygen sensor.
Specification: 8.0 to 20.0 Ohms
If a short circuit is found in the oxygen sensor heater:
-
Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-.
If oxygen sensor heater has continuity:
-
Set multimeter for voltage measurement and connect it to terminals 1 + 2 at connector to control module.
-
Start engine, and let run at idle.
-
Measure voltage supply and observe display group 41, display field 4. Htng.beh.cat.ON indicated: Specification: 11.0 to 14.5
VHtng.beh.cat.ON/Htng.beh.cat.OFF (alternating) indicated: Specification: oscillating between 0.0 and 12.0 V
-
Switch ignition off.
If there is no voltage: