volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor After Catalyst|Page 1852 > < Oxygen Sensor After Catalyst|Page 1850
Page 3
background image

If one or more of the indications in display field 1 or 2 is constant on one value:

-

Switch ignition off.

-

Test oxygen sensor wires.

Continuation

If oxygen sensor control in display field 1 does not oscillate in specified range:

-

Press the -> button.

-

Press buttons -0- and -6- to select "End Output" function 06. Press -Q- button to confirm input.

-

Perform a road test to free the Heated Oxygen Sensor (HO2S) of any possible residue, and repeat the test.

Observe the safety precautions that apply to road tests.

If specified value in display field 1 is not obtained even after road test or if value does not fluctuate at least 2 %:

-

Check oxygen sensor before Three Way Catalytic (TWC) Converter for aging. See: Aging Check 

Possible malfunctions, when static regulation of oxygen sensor is too slow:

-

The slits or holes in sensor head are clogged.

-

The ventilation hole at the sensor -near the connector cable- is closed.

-

Sensor has suffered thermal overload (glazed).

-

The sensor has been damaged by leaded fuel

Check oxygen sensor wires:

-

Connect VAG1598/31 test box to control module wiring harness. Engine Control Module (ECM) is not connected.

-

Disconnect 6-pin black harness connector -arrow- to Heated Oxygen Sensor (HO2S) -G39- before Three Way Catalytic (TWC) Converter (bank
1).

Oxygen Sensor After Catalyst|Page 1852 > < Oxygen Sensor After Catalyst|Page 1850