16-pin electrical connection, T16g - B -

1

-

+ 5V for control motors

2

-

Left Temperature Door Potentiometer/Actuator G220

3

-

Right Temperature Door Potentiometer/Actuator G221

4

-

Defroster Door Motor Position Sensor G135

5

-

Central Door Motor Position Sensor G112

6

-

Recirculation Door Motor Position Sensor G143

7

-

Back Pressure Door Motor Position Sensor G113

8

-

Left Footwell Vent Temperature Sensor G261

9

-

Right Footwell Vent Temperature Sensor G262

10

-

Fresh Air Intake Duct Temperature Sensor G89

11

-

Evaporator Temperature Sensor G308

14

-

Signal Ground (GND) potentiometer

15

-

Left Vent Temperature Sensor G150

16

-

Right Vent Temperature Sensor G151